Hart 1529 Standards Thermometer Thermometer with 4 channels for PRTs, thermistors, and thermocouples

 1529 Chub-E4 Standards Thermometer

Thermometer Readout - 4 Channels

Feature Summary

  • Four channels for PRTs, thermistors, and thermocouples
  • Displays eight user-selected data fields from any channel
  • Logs up to 8,000 readings with date and time stamps
  • Battery provides eight hours of continuous operation

Specifications

PRT / RTD

Thermistor

Thermocouple

Inputs

2 channels PRT/thermistor and 2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify when ordering; PRT/thermistor channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T, and Au-Pt TC types

Temperature Range

–189 to 960°C

–50 to 150°C

–270 to 1800°C

Measurement Range

0 to 400 W

0 to 500 KW

–10 to 100 mV

Characterizations

ITS-90, IEC-751 (DIN ‘385’), Callendar-Van Dusen

Steinhart-Hart, YSI-400

NIST Monograph 175, 3-point deviation function applied to NIST 175, 6th-order polynomial

Temperature Accuracy (meter only)

±0.004°C at –100°C

±0.006°C at 0°C

±0.009°C at 100°C

±0.012°C at 200°C

±0.018°C at 400°C

±0.024°C at 600°C

±0.0025°C at 0°C

±0.0025°C at 25°C

±0.004°C at 50°C

±0.010°C at 75°C

±0.025°C at 100°C

        Ext. RJC    Int. RJC

B at 1000°C   ±0.6°C    ±0.6°C

E at 600°C   ±0.07°C   ±0.25°C

J at 600°C    ±0.1°C    ±0.35°C

K at 600°C    ±0.15°C    ±0.4°C

N at 600°C   ±0.15°C   ±0.3°C

R at 1000°C   ±0.4°C    ±0.5°C

S at 1000°C    ±0.5°C    ±0.6°C

T at 200°C    ±0.1°C    ±0.3°C

Temperature Resolution

0.001°

0.0001°

0.01 to 0.001°

Resistance / Voltage Accuracy

0 to 20 W:  ±0.0005 W

20 to 400 W:  ±25 ppm of rdg.

0 to 5 KW:  ±0.5 W

5 to 200 KW:  ±100 ppm of rdg.

200 to 500 KW  ±300 ppm of rdg.

–10 to 50 mV:  ±0.005 mV

50 to 100 mV:  ±100 ppm of rdg.

(Internal RJC: ±0.25°C)

Operating Range

16 to 30°C

Measurement Interval

0.1 second to 1 hour; inputs may be read sequentially or simultaneously at 1 second or greater interval

Excitation Current

1mA

2 and 10 mA, automatically selected

n/a

Display

1.3” x 5” backlit LCD graphical display

Display Units

°C, °F, K, W, KW, mV

Data Logging

Up to 8,000 time- and date-stamped measurements can be logged

Logging Intervals

0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes

Averaging

Moving average of most recent 2 to 10 readings, user selectable

Probe Connection

Patented DWF Connectors accept spade lug, bare-wire, or banana plug terminations

Universal receptacle accepts miniature and standard connectors

Communications

RS-232 and IR ports included, IEEE-488 (GPIB) optional

AC Power

100 to 240V AC, 50-60 Hz, 0.4A

DC Power

12 to 16V DC, 0.5A (battery charges during operation from 14.5 to 16V DC, 1.0A)

Battery

NiMH, 8 hours operation typical without backlight, 3 hours to charge, 500 cycles

Size

4.0” H x 7.5” W x 8.2” D (102 x 191 x 208 mm)

Weight

4.5 lbs. (2 kg)

Probes from Hart

Contact Hart for a wide variety of precision PRTs, thermistors, and thermocouples

Calibration

NIST-traceable resistance certificate and NIST-traceable voltage certificate provided

So you need multiple channels, battery power, outstanding accuracy, and the ability to read PRTs, thermistors, and thermocouples. Well, here’s your answer.

Hart’s new Model 1529 Chub-E4 Thermometer gives you four channels, three major sensor types, lab-quality accuracy, and a ton of great features, all at a price you’ll love.

Inputs

The Chub-E4 has four inputs for reading four different sensors simultaneously, and we’ll configure those inputs in any of three different ways. Choose four channels of thermocouple inputs, four channels of PRT/thermistor inputs, or two channels of each. With this thermometer, reading thermocouples, PRTs, and thermistors accurately from the same device is no problem.

100-ohm or 25-ohm PRTs (with two, three, or four wires) are read using ITS-90, IEC-751 (DIN), or Callendar-Van Dusen conversion methods. Typical accuracies include ±0.006°C at temperatures below 0°C and ±0.009°C at 100°C. Thermistor readings are converted using the Steinhart-Hart polynomial or standard YSI-400 curve and are as accurate as ±0.0025°C at 25°C with four-digit resolution.

Thermocouple inputs read all the common thermocouple types, including B, E, J, K, N, R, S, T, and Au-Pt, and allow you to choose between internal and external reference junction compensation. Typical accuracy for a type J thermocouple using internal reference junction compensation at 600°C is ±0.35°C, not including the thermocouple.

PRTs and thermistors connect easily to the 1529 using Hart’s patented mini-DWF connectors, which accept bare-wire, spade lug, or miniature banana plug terminations. Thermocouples connect using standard or miniature terminations. Measurements are made each second and can be taken simultaneously or sequentially. A special high-speed mode allows measurements to be taken at the rate of 10 per second.

Display

If you think three sensor types and four inputs sounds versatile, wait until you see the display panel on the Chub-E4. Displaying measurements in °C, °F, K, ohms, or millivolts and choosing temperature resolution from 1 to 0.0001 are just the beginning.

You can also select any eight data fields to view on-screen. Choose statistical functions such as averages, standard deviations, and spreads; choose probe information such as probe type and serial number; choose T1-T2 functions using inputs from any two channels; or choose utility functions such as the date, time, and logging status. You can even save a number of screen configurations for easy recall.

The push of a front-panel button also brings up a simple menu system to easily guide you through the set-up and memory options of the 1529. Probe coefficients, sample intervals, communication settings, password settings, and a host of other functions are all easily accessible.

Choose from three combinations of inputs: 2 PRT/Thermistor and 2 TC or 4 PRT/Thermistor or 4 TC.

PRTs and thermistors connect easily with Hart’s patented mini-DWF connectors, which accept bare wire, spade lug, or banana plug terminations.

The Chub-E4 reads 2-, 3-, or 4-wire PRTs with either 25- or 100-ohm nominal resistance values. A grounding terminal is also included.

Thermocouple receptacles accept both standard and miniature connectors. The Chub-E4 reads thermocouple types B, E, J, K, N, R, S, T, and Au-PT.

Communications

The memory and communications capabilities of the Chub-E4 make it perfect for benchtop thermometry, on-site measurements, lab calibration work, and remote data logging. Optional software packages from Hart make this one of the most powerful thermometers on the market.

With battery power and memory to store up to 8,000 measurements (including date and time stamps), the 1529 has plenty of data logging capability. Store individual measurements or any number of automatic log sessions (up to 8,000 readings), each tagged with an identifying session label. Fourteen different logging intervals may be selected, from 0.1 second to 60 minutes.

With Hart’s Model 9935 LogWare II, data may be quickly downloaded to your PC for complete graphical and statistical analysis. Separate log sessions may be automatically downloaded to separate files based on session labels. With this software, the 1529 can even be used for real-time data logging. Log four channels at once directly to your PC with virtually no limit to the number of data points you take. You can analyze data, set alarm events, and even set delayed start and stop times.

With Calibrate-it software, the Chub-E4 may be integrated into a completely automated calibration system. Use one input for your reference thermometer and calibrate up to three other thermometers automatically. An RS-232 port is standard on every unit and an IEEE-488 port is optional.

More Great Features

The 1529 runs on AC power from 100 to 240 volts, DC power from 12 to 16 volts, or off its internal nickel-metal-hydride battery for up to eight hours between charging. The standard battery charges in less than three hours and lasts through 500 charge/recharge cycles.

If you want to rack mount your Chub-E4, we’ve even got a rack-mount kit for you. This unit fits on your benchtop, in your instrument rack, or in your hand.

Of course, all the reference thermometers you might need for your 1529 are available from Hart, including secondary standard PRTs, standard thermistors, and noble-metal thermocouples. Carrying cases and even a serial printer for direct printer output are also available.

We’ve said it before and we’ll keep saying it: Hart Scientific makes the best thermometer readouts in the world. No one else gives you a comparable combination of accuracy, versatility, productivity enhancing features, and price.

Ordering information
1529 Chub-E4 Thermometer, 2 TC and 2 PRT/Thermistor inputs
1529-R Chub-E4 Thermometer, 4 PRT/Thermistor inputs
1529-T Chub-E4 Thermometer, 4 TC inputs
2506-1529 IEEE Option
9322 Rugged Carrying Case, holds 1529 and four probes up to 12” long
2513-1529 Rack-Mount Kit 9935-S LogWare II, Multi Channel, Single User
9935-M LogWare II, Multi Channel, Multi User
2362 Spare AC Adapter, 15 V
9320A External Battery Pack
Downloads

Right click one of the following links and “Save Target As ...” to download the catalog pages/data sheet or a product User's Guide in Acrobat (.pdf) format.