Handheld Standards Thermometers 1521 and 1522
- Features
- Specifications
- Probes
- INFO-CON
- 1521
- 1522
- Downloads
- Reads PRTs/RTDs to ±0.025°C and thermistors to ±0.005°C
- Model 1522 logs up to 10,000 readings on-board in multiple data sets
- INFO-CON connector allows interchangeable use of calibrated probes
- INFO-CON eliminates errors from programming probe data
Specifications |
Sensor Type
|
Pt 25 to Pt 100 |
Thermistor |
Temperature
Range |
200°C
to 962°C |
50°C
to 150°C |
Resistance
Range |
0W to 400W |
0W to 500 KW |
Characterizations
|
ITS-90,
IEC-751 (DIN 385), Callendar-Van Dusen |
Steinhart-Hart
thermistor polynomial, YSI 400 (2252 ohms) |
Temperature
Accuracy (meter only) |
200°C
to 100°C: ±0.025°C
100°C to 400°C: ±0.05°C
400°C to 800°C: ±0.1°C
800°C to 962°C: ±0.15°C |
0°C to
50°C: ±0.005°C
50°C to 75°C: ±0.01°C
75°C to 100°C: ±0.02°C |
Excitation
Current |
0.5 mA |
5 mA |
Operating
Range |
0°C to 40°C |
Temperature
Resolution |
0.001° |
Measurement
Period |
1 second |
Digital
Filter |
1- to 60-second exponential filter |
Probe
Connection |
INFO-CON Connector |
Communications
|
RS-232 (Model 1522 also includes infrared interface) |
Memory |
Stores 6 readings in Hold mode
1522 Only - Logs 10,000 readings in
Auto Logging mode; logs 100 readings in Demand Logging mode.
Memory holds up to 25 data labels that may be attached to Demand Log readings or Auto Log
data sets. |
Display |
6-digit, 7-segment LCD with 16x1 alphanumeric |
Power |
Rechargeable nickel-metal-hydride batteries (AC adapter included) |
Size |
7.75" H x 4.2" W x 1.5" D (20 x 11 x 4 cm) |
Weight |
1 lb. (0.4 kg) |
Probes from
Hart |
Contact Hart for a wide variety of precision PRTs and thermistors |
Calibration
|
10-point, NIST-traceable resistance calibration provided |
With the Super-Thermometer, Black Stack, and Tweener
thermometers, Hart established itself as the clear product leader for thermometer
readouts. Our pattern of offering more power and more versatility for less money is
indisputable. Now we underline that fact by introducing the two most powerful
handheld thermometers in the world.
The Models 1521 and 1522 are the first standards thermometers to fit into
a battery-powered handheld package. Theyre as accurate as ±0.005°C!
Youll only find this level of accuracy in large desktop units that cost three
times more. Its no wonder we call the 1521 the Little Lord Kelvin of
thermometry.
Fitting easily into your hand and weighing only 1 pound (0.4 kg), these
thermometers can go anywhere. And when they get there, you can have total confidence
in the accuracy of your measurements. The 1522 has the power of a full data logger,
with memory to hold 10,000 readings.
The 1521 and 1522 read both Pt-25 and Pt-100 RTDs
as well as thermistors.
PRTs and RTDs, with their wide temperature ranges and stabilities, have
long been favored as temperature standards. From 200°C to 100°C, the 1521 reads
PRTs accurately to ±0.025°C. Even at 800°C these are high-precision readouts, accurate
to ±0.1°C.
Ultra-stable thermistors offer excellent stability and even greater
accuracies over a more narrow rangetypically from about 10°C to 110°C. At
temperatures below 50°C, these Handheld Thermometers read thermistors to ±0.005°C.
Accuracy at 100°C is ±0.02°C.
While a small number of handheld thermometers on the market offer 0.01°
resolution, they fail to provide the accuracy necessary for the last digit to be
meaningful. Harts Handheld Thermometers let you select resolution from 0.1° to
0.001° and offer the accuracy to support even 0.001° resolution.
Of course, the 1521 and 1522 let you match the exact resistance versus
temperature characteristics of an individually calibrated probe. This is true standards
thermometry. Harts Handheld Thermometers read ITS-90, Callendar-Van Dusen, or
Steinhart-Hart coefficients for maximum system accuracy. These are real algorithms, not
approximating conversion methods or electronic look-up tables. If you want to use common
industrial curves, RTDs can be read using the common DIN 43760 (IEC 751) curve and
thermistors can be read using the YSI 400 curve.
(back to top)
Probes attach to the 1521 and 1522 using Harts new
INFO-CON connector. The INFO-CON (partially based on U.S. Patent 5,857,777)
allows you to change the probes you use without requiring you to reprogram your readout. A
memory chip in the INFO-CON stores all the critical information about your probe,
including its serial number, recall date, and calibration constants.
When you connect your probe, the 1521
automatically recognizes whether youre using an RTD or thermistor and downloads the
calibration constants and type of conversion specific to your probe. It also checks the
recall date stored in the INFO-CON to verify it has not expired. To dedicate a single
probe to your readout, disable the password-protected interchangeability function and your
thermometer will read only the probe you specify.
Forget entering calibration constants yourself, and dont worry about
the mistakes that can so easily occur during that process. You dont even need to
select your sensor type. Its all stored in the INFO-CON. Simply plug in your probe
and youre ready to take readings. It doesnt get any easier.
Information is loaded into the memory of the INFO-CON by Hart when you
purchase a probe or have a probe recalibrated by Hart. Alternatively, you may load your
own information into an INFO-CON through the Handheld Thermometer or from the serial port
of your PC with the optional download adapter. The adapter includes Model 9972 software,
which provides an easy-to-use Windows interface to guide you through the loading process.
If youd like to use a Hart Handheld Thermometer with probes you
already own, no problem! Spare connectors are available. They connect easily
to your probes, and you can program them yourself.
Model 1521 LLK
The 1521 uses a menu system for convenient access to all functions.
Calibration and sensor programming functions are password protected to help prevent
unauthorized access.
Min and Max functions store the lowest and highest
readings since the last reset. The Hold function freezes and stores the
current reading (up to six may be stored) for later recall. And the Delta
function computes the difference between the current reading and a reference value, which
may be recorded at any time.
Each thermometer comes complete with rechargeable nickel-metal-hydride
batteries, an AC adapter/charger, an RS-232 cable for connecting to your PC, and a spare
INFO-CON connector. Every unit also includes a NIST-traceable calibration with
actual resistance measurements for your individual meter at 10 points4 representing
typical RTD values and 6 representing typical thermistor values.
A wide variety of standards-quality probes are
available from Hart in many different shapes, sizes, and price ranges. On pages 64
to 75 youll find PRTs as accurate as ±0.010°C and thermistors as accurate as
±0.001°C. The uncertainty of your probe should be added to the uncertainty of the meter
to compute total system uncertainty.
Model 1522 LLL
The Model 1522 has all the power and great features of the 1521 plus the
ability to log data. Two data acquisition modes are included.
In Auto Logging mode, the 1522 can store up to 10,000
measurements at user-selected intervals, including the value, unit of measure, date, and
time of each measurement. If you need more than one data set, stop recording anytime
and record as many sets as you like up to a total of 10,000 values. Once the 10,000 value
limit is reached, recording stops, so data is never lost unless you tell the 1522 to clear
its log.
The 1522 also holds as many as 25 data labels in its memory so that each
set of data can be uniquely tagged. Simply select one of the 25 labels youve created
before recording data. This label is then recorded with each measurement.
In Demand Logging mode, up to 100 individual measurements can
be recorded, each one tagged with one of the 25 data labels. Whether you need a lot
of measurements from one source or single measurements from many sources, the 1522 is a
powerful data recording tool.
With Harts 9934 LogWare or 9935 LogWare II software, data management is easy.
Data sets gathered remotely through the 1522 can be easily downloaded to a PC either
as a single file or as individual files for each data set. Link the LLL to your PC
through a serial cable or its IrDA port either as ASCII or binary files. View the data,
graph it, or apply alarms. With LogWare you can record data in real time either
from a 1522 or 1521 Thermometer.
One company consistently delivers powerful metrology products that make
your life easier. Ask other companies about their handheld thermometers. Ask
them about their thermometers that are accurate to within a few millikelvin and that
record data at the touch of a button. Then ask them to give it all to you in one
package. Hart Scientific doesat a price youll love. Call us today
and get the most powerful handheld thermometers in the world.
Right click one of the following links and Save Target As
... to download a complete data sheet or a product User's Guide in Acrobat
(.pdf) format .
Data Sheet - File size is 1064 Kb.
1521 User's Guide
- File size is 900 Kb.
1522 User's Guide
- File size is 939 Kb.
(back to top) |